The FFA-2004 HD and FFA-8004 HD are high performance four channel power amplifiers.
These amplifiers are ideally suited for use with premium cinema sound systems.
FFA’s rugged, high current power supplies respond to the lowest musical notes and audio special effects. The mechanics are built to the same exacting standards as FFA’s professional live sound and night venue products. The FFA-2004 HD features a new silent cooling system so can be installed where equipment noise would normally cause a nuisance..
These class D amplifiers use highly efficient electronic technology to run cool and use less mains supply power. The precision analogue circuits give a very stable sound stage with excellent signal to noise ratio. The sound experience is wholly musical and natural which will enhance the cinematic performance.
Designed and made in England with a 6 year warranty.
FFA-2004 HD:
4 x 500W ref 4 Ohms, 4 x 250W 8 Ohms, 4 x 1000W ref 2 Ohms
FFA-8004 HD:
4 x 2000W ref 4 Ohms, 4 x 1000W ref 8 Ohms
Any sound system that is required to deliver best audio performance
Long term power delivery in any environment
Home residential cinemas
Professional test screening rooms
Commercial cinemas
Live theatre sound
Conference rooms
AV systems
Night venues
Cruise ships
Power Ratings |
FFA-2004 HD: 4 x 500W ref 4 Ohms, 4 x 250W 8 Ohm 4 x 1000W ref 2 Ohms 4 x 2000W ref 4 Ohms, 4 x 1000W ref 8 Ohms |
Gain | FFA-2004 HD – 20dB FFA-8004 HD -28dB |
THD | THD+N Typical 0.05 4% Ohm 1kHz |
Frequency Response |
20Hz - 20kHz +- 0.5dB |
Controls | 40 Point Potentiometer per channel, power on switch |
Indicators | signal green = -20dB, signal yellow = -3dB, red signal = clip, signal red protect = over current, low AC mains or 3 sec. mute on power up |
Load Protection |
DC on output, precision clip limiter circuit |
Amplifier Protection |
Short circuit, current overload, thermal shutdown, high frequency stability circuit |
Audio Signal Inputs |
Balanced Neutrik® Female XLR input connected Pin 1 - GND, Pin 2 - Hot +, Pin 3 - Cold - . |
Audio Power Outputs |
Neutrik® speakON each channel. Channels 1 and 3 output speakON utilises 2+ and 2- connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system. Bridged output |
Power Requirement |
1 x Neutrik® 20A powerCON connector 1 x 16A 230 VAC Circuit. Power range 185V-230VAC 120V (configured at factory) |
System Cooling |
High CFM 80mm fan with proportional signal speed control. Rear to front airflow |
Dimensions | 88mm Height x 483mm Width x 510mm Depth. Includes rear rack support. 19" rack mount enclosure |
Weight | 10 kg |